Laparoscopy Full-Detachable Optical Trocar
Optical, Safety Shield
Optical Tip Auto-Locking Full-Detachable Trocar
Are you tired of struggling with traditional trocars during surgeries? Say goodbye to cumbersome setups and hello to efficiency with MD EndoGuidance Optical Tip Auto-Locking Full-Detachable Trocar. Engineered with precision and innovation, this trocar is designed to streamline your surgical procedures while ensuring patient safety.
Key Features:
- Optical Tip Technology: Our trocar features advanced optical tip technology, providing unparalleled clarity and precision during insertion.
- Auto-Locking Mechanism: With our auto-locking mechanism, you can securely fix the trocar in place with ease, minimizing the risk of displacement during surgery.
- Full-Detachable Design: Say goodbye to partial detachable trocars. Our full-detachable design allows for effortless removal, enhancing surgical efficiency.
- Versatile Compatibility: Compatible with a wide range of surgical instruments, our trocar seamlessly integrates into various procedures, offering flexibility and convenience.
Benefits:
- Enhanced Visibility: The optical tip ensures clear visualization, even in challenging surgical environments, enabling precise incision placement.
- Improved Efficiency: With auto-locking and full-detachable features, our trocar reduces setup time, allowing you to focus on what matters most—patient care.
- Patient Safety: Designed with patient safety in mind, our trocar minimizes tissue trauma and the risk of accidental dislodgement, promoting better outcomes.
Technical Specifications:
- Auto-locking Mechanism:
- The trocar features an integrated auto-locking mechanism based on precision engineering.
Activation is seamless, triggered upon full insertion, ensuring a secure and stable placement during procedures.
- The mechanism engages automatically and can only be released intentionally, reducing the risk of unintentional dislodgment.
- Full-detachable Trocar Optical System:
- Bladeless visible tip, less trauma.
- Realizing the visualization of tissue layers during the penetration.
- Safety Shield:
- The safety shield is a pivotal component, providing an additional layer of protection during trocar insertion and withdrawal.
- Constructed from biocompatible materials, the shield is designed to prevent accidental injuries without compromising visibility or maneuverability during procedures.
- Material Composition:
- Trocar components are crafted from medical-grade materials to ensure biocompatibility and minimize the risk of adverse reactions.
- Stainless steel is used for critical components to enhance durability and corrosion resistance.
|
Primary Seal
|
|
Secondary Seal
|
Funneled entry maintaining airtightness during instrument use and instrument exchange.
|
Cross-entry guarantees airtightness
when instruments are not in use
|
Optical Tip
- Auto-shield for easy penetration allows less trauma and quick recovery.
|
Auto-locking Trocar
|
|
|
|
|
Item No.
|
Size
|
|
MDO5-100
|
5mm x 100mm
|
|
MDO5-150
|
5mm x 150mm
|
|
MDO10-100
|
10mm x 100mm
|
|
MDO10-150
|
10mm x 150mm
|
|
MDO12-100
|
12mm x 100mm
|
|
MDO12-150
|
12mm x 150mm
|
|
MDO15-100
|
15mm x 100mm
|
|
MDO15-150
|
15mm x 150mm
|
|
|
|
|
|
|
Usage Guidelines:
- Procedure Compatibility:
- The trocar is suitable for a variety of medical procedures, including laparoscopic surgeries and minimally invasive interventions.
- Healthcare professionals should ensure that the trocar is compatible with the specific procedure and patient requirements.
- Assembly and Disassembly:
- Follow the provided guidelines for proper assembly and disassembly of the trocar.
- Ensure that the blade is securely attached during use and properly detached during the cleaning and sterilization process.
- Sterilization Procedures:
- The trocar is designed to withstand standard sterilization methods, including autoclaving.
- Follow recommended sterilization guidelines to maintain the integrity and safety of the device.
- Storage Conditions:
- Store the trocar in a clean, dry environment, avoiding exposure to extreme temperatures or direct sunlight.
- Follow manufacturer recommendations for storage conditions to preserve the device's functionality.
Precautions:
- Sharp Blade Awareness:
- Handle the trocar with caution, especially during blade attachment and detachment.
- Always be aware of the sharpness of the blade to prevent accidental injuries.
- Proper Disposal:
- Dispose of the trocar according to local regulations and medical waste disposal guidelines.
- Take precautions to prevent needle-stick injuries during disposal.
- Single-use Consideration:
- The trocar is designed for single-use; do not attempt to reuse the device.
- Reusing the trocar may compromise safety and performance.
- Training and Certification:
- Only qualified and trained healthcare professionals should handle and use the trocar.
- Certification in the proper use of trocars and related safety procedures is recommended.
Contraindications:
This device is not intended for use when endoscopic techniques are contraindicated.
Note
This product information is provided for reference purposes. Please consult the detailed product documentation and adhere to your institution's guidelines for usage and sterilization procedures.
|
Sterilized by Ethylene Oxide
|
You can download this product insert
You can download this product flyer
|
|
 |